Alliance Laundry Systems SW039 Washer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation/Operation Supplement
21
9001014
Machine Foundation
Thoroughness of detail must be stressed with all
foundation work to ensure a stable unit installation,
eliminating possibilities of excessive vibration during
extract.
The washer-extractor must be placed on a smooth level
surface so that the entire base of the machine is
supported and rests on the mounting surface.
The standard installation does not require anchoring
unless mandated by state or local codes.
Static and dynamic loads on the floor or foundation are
shown in Table 2.
Table 2 can be used as a reference when designing
floors and foundations.
Ensure that the machine is installed on a
level floor of sufficient strength and that
the recommended clearances for
inspection and maintenance are provided.
Never allow the inspection and
maintenance space to be blocked.
W488
CAUTION
Floor Load Data
Model 18 25 35 55 75 100 135 165
Static floor
load
2.51 kN
(546 lb.)
2.63 kN
(592 lb.)
4.38 kN
(983 lb.)
6.97 kN
(1566 lb.)
10.3 kN
(2310 lb.)
16.4 kN
(3682 lb.)
19.1 kN
(4282 lb.)
24.49 kN
(5509 lb.)
Static
pressure
6.79 kN-m
2
(137 lbs-ft
2
)
5.17 kN-m
2
(109 lbs-ft
2
)
6.53 kN-m
2
(137 lbs-ft
2
)
8.33 kN-m
2
(175 lbs-ft
2
)
8.97 kN-m
2
(188 lbs-ft
2
)
11.5 kN-m
2
(240 lbs-ft
2
)
12.5 kN-m
2
(261 lbs-ft
2
)
14.84 kN-m
2
(310 lbs-ft
2
)
Dynamic
floor load
0.7 kN
(157 lb.)
0.75 kN
(169 lb.)
1.2 kN
(270 lb.)
1.7 kN
(382 lb.)
2.0 kN
(450 lb.)
2.96 kN
(665 lb.)
3.75 kN
(883 lb.)
4.86 kN
(1093 lb.)
Maximum
dynamic
load
0.7 kN
(157 lb.)
0.75 kN
(169 lb.)
1.2 kN
(270 lb.)
1.7 kN
(382 lb.)
2.0 kN
(450 lb.)
2.96 kN
(665 lb.)
3.75 kN
(883 lb.)
5.78 kN
(1301 lb.)
Dynamic
pressure
1.89 kN-m
2
(39.4 lbs-ft
2
)
1.47 kN-m
2
(31.1 lbs-ft
2
)
1.79 kN-m
2
(37.6 lbs-ft
2
)
2.03 kN-m
2
(42.7 lbs-ft
2
)
7.75 kN-m
2
(36.6 lbs-ft
2
)
2.07 kN-m
2
(43.3 lbs-ft
2
)
2.46 kN-m
2
(53.8 lbs-ft
2
)
3.05 kN-m
2
(63.7 lbs-ft
2
)
Table 2