Grounding Information
This dryer must be connected to a grounded
metal, permanent wiring system; or an
equipment-grounding conductor must be run
with the circuit conductors and connected to the
equipment-grounding terminal or lead on the
dryer.
The dryer has its own terminal block that must be
connected to a separate branch, 60 Hertz, single
phase circuit, AC (alternating current) circuit,
fused at 30 Amperes (the circuit must be fused
on both sides of the line). Electrical service for
the dryer should be of maximum rated voltage
listed on the nameplate. Do not connect dryer
to 110, 115, or 120 Volt circuit.
Heating elements are available for field
installation in dryers which are to be connected to
electrical service of different voltage than that
listed on nameplate, such as 208 Volt.
If branch circuit to dryer is 15 feet (4.57 m) or
less in length, No. 10 AWG wire (copper wire
only), or as required by local codes. If over 15
feet (4.57 m), use No. 8 AWG wire (copper wire
only), or as required by local codes. Allow
sufficient slack in wiring so dryer can be moved
from its normal location when necessary.
The power cord connection between wall
receptacle and dryer terminal block IS NOT
supplied with dryer. Type of power cord and
gauge of wire must conform to local codes.