19
Installation
F232062
Cylinder Speeds
Gentle wash/reverse speed, rpm 29 27 26 24 22
Wash/reverse speed, rpm 5248464340
Distribution speed, rpm 8277736863
Low extract speed, rpm 366 343 328 307 280
Medium extract speed, rpm* 534 500 478 447 408
High extract speed, rpm 685 641 613 573 524
Centrifugal Force Data
Gentle wash centrifugal force, Gs 0.25 0.25 0.25 0.25 0.25
Wash/reverse centrifugal force, Gs 0.8 0.8 0.8 0.8 0.8
Distribution centrifugal force, Gs 2 2 2 2 2
Low extract centrifugal force, Gs 40 40 40 40 40
Med. extract centrifugal force, Gs 85 85 85 85 85
High extract centrifugal force, Gs 140 140 140 140 140
Balance Detection
Vibration safety switch installed N/A N/A Standard Standard Standard
Direct Steam Heating (Optional)
Steam inlet connection size, in (mm) 1/2 (13) 1/2 (13) 1/2 (13) 1/2 (13) 1/2 (13)
Number of steam inlets 1 1 1 1 1
Steam req. to raise bath
temperature 10°F, lb
(10°C, kg)
LOW 1.1 (0.50) 1.4 (0.64) 2.1 (0.95) 2.8 (1.3) 4.4 (2.0)
HIGH 1.4 (0.64) 1.9 (0.86) 2.7 (1.2) 3.7 (1.7) 6.3(2.9)
Average steam use per cycle, BHP 0.72 0.96 1.4 1.9 3.1
Electrical Heating (Optional)
Total electrical heating capacity, kW 7.8 7.8 15.6 23.4 31.2
Electrical heating elements 3 3 6 9 12
Electrical heat element size, kW 2.6 2.6 2.6 2.6 2.6
*Medium extract speed is not available on Electronic Control (EC) models.
Cabinet Hardmount General Specifications
Variable-Speed Models (Continued)
Specification 18 27 35 50 80