Display Indications for V-Series – Non-Coin
Display Meaning Display Meaning
FP 1 Program identification code (ROM)
(this is an example only)
nEd
Medium water level
HI High water level
HoLd Wait...power has just been turned on SUP1 Supply 1
CY Cycle (followed by two-digit number) SUP2 Supply 2
tESt/CYC* Test cycle selected SUP3 Supply 3
FAr Degrees Fahrenheit SUP4 Supply 4
CEL Degrees Celsius SUP5 Supply 5 (Setup option)
HEAt Auxiliary heat enabled SUP6 Supply 6 (supply 1 and 5)
noHt Auxiliary heat disabled SUP7 Supply 7 (supply 3 and 4)
tFIL Temperature-controlled fill enabled SLo/For Gentle wash speed, forward direction
ntFL Temperature-controlled fill disabled SLo/rEv Gentle wash speed, reverse direction
CooL Automatic cool-down enabled
nor
n/For
Normal wash speed, forward direction
noCL Automatic cool-down disabled
nor
n/rEv
Normal wash speed, reverse direction
Ag 1 Agitation 1 selected (90% agitation) drAI Drain enabled
Ag 2 Agitation 2 selected (33% agitation) nodr Drain disabled
Ag 3 Agitation 3 selected (10% agitation) dISt Distribution (load balancing before extract)
Ag 4 Agitation 4 selected (6.7% agitation)
SPIn/tI
nE*
Reads “SPIn” for one second, then
“tI
nE” followed by time for spin
AgSn Agitation speed normal
AgSL Agitation speed low SPn1 Lowest of three spins
PU
nP
Pump output enabled (future use only) SPn2 Middle of three spins
nP
nP
Pump output disabled (future use only) SPn3 Highest of three spins
PrE Prewash segment (1st of 11 segments) STOP Stop routine
UASH Wash segment (2nd of 11 segments) SdLY Spin coast delay
FIL1 First fill (3rd of 11 segments) dOnE Cycle and stop routine have ended
FIL2 Second fill (4th of 11 segments) dFLt Drive fault detected
FIL3 Third fill (5th of 11 segments) dOOr Door not properly closed
FIL4 Fourth fill (6th of 11 segments) bAL/FAIL* Balancing routine failed during test cycle
after 10 attempts to balance load
FIL5 Fifth fill (7th of 11 segments)
FIL6 Sixth fill (8th of 11 segments) FILL/STOP* Programmed water level not reached after 30
minutes
FIL7 Seventh fill (9th of 11 segments)
FIL8 Eighth fill (10th of 11 segments) FULL The computer detects low water level or
higher when none should be present
FIL9 Ninth fill (11th of 11 segments)
CFIL Cold fill rotA Computer detects possible rotation of motor
when there should be none
bFIL Warm fill (both hot and cold)
HFIL Hot fill tSFL Temperature sensor failure or temperature
out of range
AFIL Auxiliary fill (Setup option)
Lo Low water level
* Display indications separated by a slash (/) represent a flashing display.