16
ANTI-WRINKLE PROGRAM (Grd)
This feature can be used in conjunction with any of the three (3) operating modes (Coin Mode, Auto Mode, or
the Free Dry Mode). In this program (“Grd”), when the drying and cooling cycles are completed, the dryer will
shut off, the buzzer (tone) will sound, and the light emitting diode (L.E.D.) display will read “donE.” If the door
is not opened, the Phase 5 coin microprocessor controller (computer) will wait until the “Guard Delay Time”
(PL15) has expired, at which time the clothes
will be tumbled (without heat) for the programmed ”Guard On
Time” (PL15). The Phase 5 coin microprocessor controller (computer) will repeat this process until the
programmed “Active Guard Time” (PL16) has expired or until the dryer door is opened, at which time the
L.E.D. display will read “FILL” and/or “Amount To Start” (“AtSt”) or “FILL” and/or “FrEE.”
NOTE: When programming the use of the Anti-Wrinkle Program (“Grd”), the following parameter/
programs need to be checked and/or changed accordingly:
PL01 ................................ “Grd” (Anti-Wrinkle Program active)
................................ “bUZ” or “nbUZ” (buzzer [tone] active/not active)
PL15 ................................ “GdLY” (guard delay time)
................................ “Gont” (guard on time)
PL16 ................................ “AGt” (active guard time)
BUZZ/TONE (bUZ)
With the Anti-Wrinkle Program active, the option is available to have the buzzer/tone (“bUZ”) sound for a period
of 5-seconds at the end of each “Guard On Time” cycle, or, no buzzer (“nbUZ”) sound.
FREE DRY MODE (FrEE)
The Phase 5 coin microprocessor controller (computer) can be programmed to run without the insertion of
coins. When the Phase 5 coin microprocessor controller (computer) is in the “FrEE” dry mode, it may be
programmed to run in the “AUtO” (Automatic) Mode or the “tInE” (Timed) Mode.
NOTE: When programming the use of the Free Dry Mode (“FrEE”), the following parameters/
programs need to be checked and/or changed accordingly;
PL01 ................................ “AUtO” (automatic drying cycle) or
................................ “tInE” (timed drying cycle) “FrEE”
PL02* .............................. “PdrY” (percent dry)
PL14* .............................. “Adrt” (maximum auto dry time)
PL17* .............................. “A” and “b” factors
* Needs to be programmed only if PL01 “AUtO” Cycle is chosen.