Arc Suppressor (A.S.) Relay Board Listing
* ADC Part No. 137151 Solid State Relay (SSR) Board cannot be used with 3-phase (3ø) motors.
IMPORTANT: Check label on Arc Suppressor (A.S.) Board to verify correct part number.
NOTE: Solid State Relay (SSR) Boards (ADC Part No. 137150 and ADC Part No. 137151) can be used
in place of electromechanical relay boards as noted.
TYPE
OF
HEAT
ELECTRIC VOLTAGE
ARC SUPPRESSOR (A.S.)
RELAY BOARD
PART NUMBERS
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
(CONTROL VOLTAGE)
120 VOLT 208/230 VOLT
GAS
Glo Bar Non-Hi/Lo 120 2 137077 or 137150 ---
Glo Bar Non-Hi/Lo 208/230 2 --- 137079
Glo Bar Non-Hi/Lo 208-480 3 --- 137079
Glo Bar Hi/Lo 120 2 137077 or 137150 ---
Glo Bar Hi/Lo 208/230 2 137077 ---
Glo Bar Hi/Lo 208-480 3 --- 137079 or 137150
Direct Spark Ignition (DSI) 120 2 137076 or 137151 ---
Direct Spark Ignition (DSI) 208/230 2 --- 137078 or 137151
Direct Spark Ignition (DSI) 208-480 3 --- 137078
ELECTRIC
20 Kw through 30 Kw 208/230 2 --- 137078 or 137151
208-480 3 --- 137078 or 137151*
208 4 137076 or 137151* ---
380-480 4 --- 137078 or 137151*
STEAM
Low Pressure 120 2 137076 or 137151 ---
Low Pressure 208/230 2 --- 137078 or 137151
Low Pressure 208-480 3 --- 137078
High Pressure 120 2 137076 or 137151 ---
High Pressure 208/230 2 --- 137078 or 137151
High Pressure 208-480 3 --- 137078