ADC AD-295 Clothes Dryer User Manual


 
41
J. PROGRAM LOCATION 07 (PL07)
Perm Press Temp
Location to be viewed/changed.
Press “Perm Press” key.
Display will read “PP°F,” “Perm Press”
temperature key status for 3-seconds
and then actual temperature programmed.
If no change, press “Perm Press” key
otherwise press “HI” or “LO” keys
and then “Perm Press.”
Temperature Decrease Temperature Increase
Summary: Perm Press Temp is programmable from a minimum of 100° F to a maximum of 190° F in
ten-degree increments or from a minimum of 38° C to a maximum of 88° C in five-degree increments.
For the AD-26 and AD-295 any three (3) of the selections (HI/LO/PP) are programmable from a
minimum of 100° F to a maximum of 170° F in ten-degree increments or from a minimum of 38° C
to a maximum of 77° C in five-degree increments.
For the AD-540 and WDA-540 any three (3) of the selections (HI/LO/PP) are programmable
from a minimum of 100° F to a maximum of 160° F in ten-degree increments or from a minimum of
38° C to a maximum of 71° C in five-degree increments.
PL07
PP°F
Perm Press
150F HI Temp
Perm Press
LO Temp
Refer to
Section V
for instructions
on entering program locations.
(Wait 3-Seconds)
Automatically goes into PL08 Program without PL08 Display Mode
Continued on next page