Whirlpool WGD7800X Clothes Dryer User Manual


 
Gas Dryer
PRODUCT MODEL NUMBERS
WGD6200S, WGD6600V, WGD6600W,
WGD7300X, WGD7400X, WGD7600X,
WGD7800X
Gas supply: This dryer is equipped for use with Natural
gas. Dryer can be converted to L.P. gas. When rigid
pipe is used it should be 1/2" IPS. When acceptable
to the gas supplier and local codes, 3/8" approved
tubing may be used for lengths under 20 ft (6.1 m).
For lengths over 20 ft (6.1 m), larger tubing should be
used. Pipe-joint compounds resistant to the action of
L.P. gas must be used. An individual manual shutoff
valve must be installed within 6 ft (1.8 m) of the dryer
in accordance with the National Fuel Gas Code ANSI
Z223.1.
Electrical: A 120-volt, 60 Hz, AC-only, 15 or 20 amp
fused electrical supply is required. A time-delay fuse or
circuit breaker and a separate circuit are recommended.
Water (Steam models only): The dryer must be
connected to the cold water faucet using new inlet
hoses. Do not use old hoses. Do not overtighten.
Damage to the coupling can result.
4"
(102 mm)
2½"
(64 mm)
4"
(102 mm)
4"
(102 mm)
B
A
A. Louvered hood
B. Box hood
C. Angled hood (acceptable)
C
Number of
90 turns
or elbows
T ype of
vent
Box or
Louvered
hoods
Angled
hoods
0
Rigid metal
64 ft (20 m)
58 ft (17.7 m)
1
54 ft (16.5 m)
48 ft (14.6 m)
2
44 ft (13.4 m)
38 ft (11.6 m)
3
35 ft (10.7 m)
29 ft (8.8 m)
4
27 ft (8.2 m)
21 ft (6.4 m)
Rigid metal
Rigid metal
Rigid metal
Rigid metal
o
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation
our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
Ref. W10261614B
05/2010
OVERALL DIMENSIONS
Dryer dimensions
Select the route that will provide the straightest and
most direct path outdoors. Plan the installation to use
the fewest number of elbows and turns. Use the fewest
90° turns possible.
Do not use vent runs longer than specied in vent
length chart.
Determine the number of elbows you will need.
For closet installation, with a door, the
minimum ventilation openings in the top
and bottom of the door are required.
Louvered doors with equivalent air
ventilation openings are acceptable.
For cabinet installation, with a
door, the minimum ventilation
openings in the top are required.
29"
(737 mm)
22
1
/
4
"
(565 mm)
29
1
/
4
"
(743 mm)
43
1
/
2
"
(1105 mm)
14" max.*
(356 mm)
A
B
C
29"
(737 mm)
5"
(127 mm)
1"
(25 mm)
1"
(25 mm)
18"*
(457 mm)
3"*
(76 mm)
3"*
(76 mm)
29
1
/
4
"
(743 mm)
48"
2
*
(310 cm
2
)
24"
2
*
(155 cm
2
)
Exhaust venting: Exhaust your dryer to the outside.
4" (102 mm) diameter vent is required. Rigid or exible
metal exhaust vent must be used. Do not use plastic
or metal foil vet. Exhaust hood must be at least
12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
Hood styles: A & B are recommended.
The vent system chart provides venting requirments
that will help to achieve the best drying performance.
Vent system chart:
NOTE: Side and bottom exhaust installations have
a 90° turn inside the dryer. To determine maximum
exhaust length, add one 90° turn to the chart.
Cabinet and Closet dimensions