Whirlpool 3977631 Clothes Dryer User Manual


 
11
FRONT
STACK STAND
CLOSET
DOOR
SIDE
STACK STAND
DRYER
WASHER
SIDE
FRONT
DRYER DRYER
12"
12"
1"
3"
48 sq in
24 sq in
3"
3"
18"
14"
MAX.
1"
1"
3"
May be 0" clearance.
††
Opening is minimum for closet door. Louvered door with air opening is acceptable.
†††
Additional space may be needed for exhaust elbow.
INSTALLATION INSTRUCTIONS
NOTE: Check codes requirements. Some
codes limit or do not permit installation of
clothes dryers in garages, closets, mobile
homes, or sleeping quarters. Contact your
local building inspector.
This dryer may be installed in a recessed
area or closet. If closet door is installed,
the minimum unobstructed air openings in
top and bottom are required. Louvered
doors with equivalent air openings are
acceptable.
Your dryer needs a certain amount of
space around it for proper ventilation and
for easier installation and servicing. The
following minimum installation spacings are
required when the unit is to be operated
with or without the Stack Stand Kit. To
purchase a Stack Stand Kit, see the
“Assistance or service” section. For ease of
installation and service, additional spacing
should be considered.
WARNING: To reduce the risk of fire,
this appliance MUST BE EXHAUSTED
OUTDOORS.
NOTE: No fuel-burning appliances may be
installed in the same closet as a dryer.
Recessed area and closet installation
Minimum installation spacing
3977631 v12 c51 3/22/99 5:11 PM Page 11