Pelco C2479M-A Washer Accessories User Manual


 
EH8000RKIT
Dry Nitrogen Charging Kit
C2479M-A (11/04)
®
The EH8000RKIT is used to charge the EH8100 Series pressurized enclosures and the Pressurized Spectra III
TM
Series domes with approximately 8 psi of dry
nitrogen.
WARNING: This kit utilizes a regulator that has a fixed, nonadjustable output pressure of 12 psi (83 kPa). The gauge reads the tank pressure only. This
can be used to determine how much pressure is in the tank and when it is necessary to replace the tank. The tank is non-rechargeable.
1. Open the tank valve.
2. EH8100 Series Enclosure Only – To reduce the time necessary to purge the air from the enclosure, position the enclosure so that the window is
pointing up. Use a small screwdriver to hold the pressure relief valve open. Refer to Figure 1.
SCHRAEDER
VALVE
PRESSURE
RELIEF VALVE
T-HANDLE
Figure 1. EH8000 Series Enclosure - Rear View
3. Remove the valve cap from the Schraeder valve and attach the air chuck. Refer to Figures 1 and 2.
Figure 2. Pressurized Dome