Miele T 560 C Clothes Dryer User Manual


 
Electrical connection
For U.K. only:
This tumble dryer is supplied ready for
connection to an a.c. single phase 230 V,
50 Hz supply. The rated load is 2.9 kW.
The machine is supplied with a 2 m long
mains cable with moulded plug and the
fuse rating is 13 A. The appliance should
be connected up only by a qualified elec-
trician, in accordance with national and
local safety regulations.
For other countries:
This tumble dryer is supplied ready for
connection to an a.c. single phase 220 V,
60 Hz supply. The rated load is 2.86 kW.
The machine is supplied with a 2 m long
mains cable with moulded plug and the
fuse rating is 16 A. The appliance should
be connected up only by a qualified elec-
trician, in accordance with national and
local safety regulations.
Connection should be made via a
fused plug and a suitable switched
socket which is easily accessible.
For extra safety it is advisable to install
a residual current device (RCD) with a
trip current of 30 mA.
The voltage, rated load and fuse rating
are given on the data plate. Please en-
sure that these match the household
mains supply.
Important
The wires in the mains lead are coloured
in accordance with the following code:
Green/yellow = earth
Blue = neutral
Brown = live
As the colours of the wires in the mains
lead of this appliance may not corre-
spond with the coloured markings ident-
ifying the terminals in your plug, pro-
ceed as follows:
The wire which is coloured green and
yellow must be connected to the termi-
nal in the plug which is marked with the
letter E or by the earth symbol z or
coloured green or green and yellow.
The wire which is coloured blue must be
connected to the terminal which is marked
with the letter N or coloured black. The
wire which is coloured brown must be
connected to the terminal which is
marked with the letter L or coloured red.
WARNING
THIS APPLIANCE MUST BE EARTHED.
Non-rewireable plugs BS 1363 (U.K.)
If this machine or appliance is fitted
with a non-rewireable plug, the follow-
ing information applies:
If the socket outlets are not suitable for the
plug supplied with this product, it must be
cut off and an appropriate plug fitted. The
plug cut from the flexible cord should be
disposed of and on no account be in-
serted into a 13 A socket elsewhere in the
house (electric shock hazard). The fuse
cover must be refitted when changing the
fuse, and if the fuse cover is lost, the plug
must not be used until a suitable replace-
ment is obtained. The colour of the correct
replacement cover is that of the coloured
insert in the base of the plug, or the colour
that is embossed in words in the base of
the plug (as applicable to the design of
plug fitted). The correct fuse rating of the
replacement fuses that are ASTA ap-
proved to BS 1362 should be fitted. Re-
placement fuse covers may be purchased
from your local electrical suppliers, elec-
tricity showroom, or Miele Service
Agent.
21