Miele T8402C Clothes Dryer User Manual


 
Extending the cooling down
time
The cooling down phase which takes
place before the end of a programme
can be lengthened if required. This
makes the garments easier to handle.
The dryer is delivered with the
extended cooling down time option
deactivated. You can extend the
cooling down time by 5 minutes or 10
minutes.
The option of extending the cooling
down time is available with the Cottons,
Minimum iron and Automatic
programmes.
Follow the steps (A,B,C ...) to
programme and store in memory.
Before you begin, ensure that:
The tumble dryer is switched off.
The door is closed.
The programme selector is at Finish.
APress the Start button and keep it
pressed in whilst carrying out steps
B-C.
BSwitch the dryer on.
CWait until the Start indicator lamp
lights up constantly...
D. . . and then release the Start button.
ETurn the programme selector to
Smoothing.
The Cool air lamp will flash seven times.
The flashing sequence of the
Drying lamp shows which option is
currently selected.
If the Drying indicator lamp is not
flashing: the cooling down time is
not extended (factory default
setting).
If the Drying lamp flashes once:
the cooling down time will be
extended by five minutes.
If the Drying lamp flashes twice:
the cooling down time will be
extended by ten minutes.
FPressing the Start button switches
between the 3 options.
GSwitch the dryer off.
The setting you have selected is now
stored in memory. You can change it
again at any time.
To check the setting:
^
Carry out steps A to E.
^
Switch the dryer off after checking
the setting as described above.
Programmable functions
47