Part 4 ELECTRICAL REQUIREMENTS FOR ELECTRIC DRYERS
a. 3-wire receptacle (NEMA type 10-30R)
b. 3-wire plug
c. Neutral prong
d. Spade terminals with up turned ends
e. 3/4 in. (1.9 cm) UL approved strain relief
f. Ring terminals
g. Neutral (white or center wire)
a. External ground connector
b. Neutral grounding wire (white)
c. Center silver-colored terminal block screw
d. Neutral wire (white or center wire)
e. 3/4 in. (1.9 cm) UL-listed strain relief
1. Loosen or remove center terminal block screw.
2. Connect neutral wire (white or center wire) of
power supply cord to the center, silver colored
terminal screw of the terminal block. Tighten
screw.
3. Connect the other wires to outer terminal block
screws. Tighten screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of
dryer rear panel. Secure cover with hold-down
screw.
e
a
d
b
c
d
gf
a
lf your local codes or ordinances permit the
connection of a frame-grounding conductor to the
neutral wire, use these instructions. If your local
codes or ordinances do not allow the connection of
a frame-grounding conductor to the neutral wire,
use the instructions under Section 3: Optional
3-wire connection.
Option 1: 3-Wire Connection with
a Power Supply Cord