29" (73.7 cm) Electric Dryer
P
RODUCT MODEL NUMBERS
P
RODUCT DIMENSIONS
RECESSED AREA AND CLOSET INSTALLATION
EXHAUST VENTING
E
ED4400W
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10150612B
07/2009
22
3
/4"
(578 mm)
43
3
/8"
(1102 mm)
*27
3
/4"
(705 mm)
29
"
(737 mm)
29"
(737 mm)
*26
"
(660 mm)
43
3
/8"
(1102 mm)
15
1
/4"
(387 mm)
43
3
/8"
(
1102 mm)
*27
3
/4"
(705 mm)
29"
(737 mm)
22
3
/4"
(578 mm)
43
3
/8"
(1102 mm)
*27
3
/4"
(705 mm)
29
"
(737 mm)
13
3
/4"
(349 mm)
A
B
C
D
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
A
B
C
18"*
(457 mm)
1"
(25 mm)
29"
(737 mm)
1"
(25mm)
1"*
(25mm)
14"max.*
(356
mm)
27¾"
(705mm)
5"*
(127mm)
48in.
(310cm )
2
*
2
24 in.
(150cm )
2
*
2
3"*
(76mm)
3"*
(76mm)
For closet installation
with a door, minimum
ventilation openings in
the top and bottom of
the door are required.
Louvered doors with
equivalent air openings
are acceptable.
1. Select the route that will provide the straightest and most direct path outdoors. Plan the
installation to use the fewest number of elbows and turns. When using elbows or making turns,
allow as much room as possible. Bend vent gradually to avoid kinking. Use the fewest 90° turns
possible.
2. Determine vent length.
The maximum length of the exhaust system depends upon:
• The type of vent (rigid metal or flexible metal).
• The number of elbows used.
• Type of hood.
See the exhaust vent length chart that matches your hood type for the maximum vent lengths you
can use.
3. Determine the number of elbows you will need.
IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.
Number of
90 turns
or elbows
Type of
vent
Box or
Louvered
hoods
Angled
hoods
0
Rigid metal
64 ft (20 m)
58 ft (17.7 m)
1
54 ft (16.5 m)
48 ft (14.6 m)
2
44 ft (13.4 m)
38 ft (11.6 m)
3
35 ft (10.7 m)
29 ft (8.8 m)
4
27 ft (8.2 m)
21 ft (6.4 m)
Rigid metal
Rigid metal
Rigid metal
Rigid metal
o
Electrical: To supply the required three- or four-
wire, single-phase, 120/240-volt, 60-Hz, AC-only
electrical supply (or three- or four-wire,
120/208-volt electrical supply, if specified on the
serial/rating plate) on a separate 30-amp circuit,
f
used on both sides of the line. A time-delay fuse
or circuit breaker is recommended. Connect to an
individual branch circuit. Do not have a fuse in the
neutral or grounding circuit.
Exhaust venting: Exhaust your dryer to the
outside. 4" (102 mm) diameter heavy metal exhaust
vent and clamps must be used. DURASAFE™
venting products are recommended. For best drying
performance, rigid metal vents are recommended.
Flexible metal vents are acceptable only if accessible
for cleaning. Do NOT use plastic or metal foil vent.
Exhaust outlet hood must be at least 12" (304 mm)
from the ground or any object that may be in the
path of the exhaust.
A. Small Opening
Side-Swing Door
B. Large Opening
Side-Swing Door
C. Wide Opening
Side-Swing Door
D. Wide Opening
Hamper Door
*Most installations require a minimum 5" (127 mm) clearance behind the dryer for exhaust
vent with elbow.
Louvered style
4"
(102 mm)
4
"
(102 mm)
Box hood style
4"
(102 mm)
Angled style
2
1
/
2
"
(64 mm)
Vent System Chart
NOTE: Side and bottom exhaust installations have
a 90° turn inside the dryer. To determine maximum
exhaust length, add one 90° turn to the chart.