Unpacking/General Installation (All Dryers)
All Cissell dryers are packed in a protective (heavy-duty) plastic bag.
Upon arrival of the equipment, any damage in shipment should be
reported to the carrier immediately.
Upon locating permanent location of a unit, care should be taken in
movement and placement of equipment.
See outline clearance diagrams for correct dimensions.
Remove all packing material such as: tape, manuals, skid, etc. On
gear reducer models, remove screw and insert vent found in basket.
Leveling: Use spirit level on top of dryer. Adjust leveling bolts on
dryer (see adjustable leveling bolts in maintenance section).
Check voltage and amperes on rating plate before installing the dryer.
The construction of Cissell dryers permits installation side-by-side to
save space or to provide a wall arrangement. Position dryer for the
least amount of exhaust piping and elbows, and allow free access to
the rear of dryer for future servicing of belts, pulleys and motors.
Installation clearance from all combustable material is 12” ceiling
clearance, 24” rear clearance, and 0” side clearance.
Before operating dryer, open basket door and remove blocking
between front panel and basket. Read the instruction tags, owner's
manual, warnings, etc.
IMPORTANT
Opening the clothes loading door deactivates the door switch
to shut off the motors, fan, gas, steam, or electric element. To
restart the dryer, close the door and press in the push to start
button and hold briefly.
IMPORTANT
This dryer is designed for a capacity maximum load.
Overloading it will result in long drying times and damp spots
on some clothes.
IMPORTANT
Maximum operating efficiency is dependent upon proper air
curculation. The lint screen must be kept cleaned daily to
insure proper air circulation throughout the dryer.
IMPORTANT
Provide adequate clearance for air opening into the combustion
chamber.