Troubleshooting Chart—Gas, Steam, and Electric Dryers
TROUBLE CAUSE REMEDY
Check fuses on Circuit Breakers. Make sure Main Control
Switch is ON.
Check power source; voltage, phase and frequency must be
the same as specified on Electrical Rating Plate.
Turn timer clockwise to desired time setting.
Check wire connections in electrical box on rear of dryer.
Check coils and contacts.
Check voltage at motor terminals. Voltage must be within
+ 10% of voltage shown on Motor Rating Plate. If not,
Check with local power company for recommended
corrective measures.
Check with local power company to insure that wiring is
adequately sized for load.
Check all electrical connections and tighten any loose
connections.
Check Installation Sheet in Service section for
recommended make-up air openings.
Clean lint accumulation on and around motors.
Close door.
Adjust switch by removing cover and bend Actuator Lever
to clear Switch Button 3/8" with cover in place.
Replace switch.
Replace contactor.
Replace V-Belt.
Adjust belt tension.
Tighten set screw.
Remove load.
No power.
Incorrect power.
Time off.
Loose wiring
connections.
Defective starting
relay.
Low voltage.
Inadequate wiring.
Loose connections.
Inadequate air.
Poor housekeeping.
Loading door
OPEN.
Door Switch out of
adjustment.
Defective Door
Switch.
Defective Basket
Motor Contractor.
V-Belt broken.
V-Belt loose.
Motor Pulley
loose.
Basket overloaded.
Motor will not start.
Motor tripping on thermal
overload.
Basket motor will not run.
Motor runs, but basket will
not revolve.