American Dryer Corp. AD-310 Clothes Dryer User Manual


 
29
4. GAS MODELS - The sail switch damper assembly was installed and adjusted at the factory prior to
shipping. However, each sail switch adjustment must be checked to assure that this
important safety control is functioning.
5. GAS MODELS - Be sure that ALL gas shutoff valves are in the open position.
6. Be sure ALL side and base panels are on the dryer.
7. Check ALL service doors to assure that they are closed and secure.
8. Be sure lint drawer is securely in place.
NOTE: LINT DRAWER MUST BE ALL THE WAY IN PLACE TO ACTIVATE SAFETY
SWITCH OTHERWISE THE DRYER WILL NOT START.
9. Rotate the basket (tumbler/drum) by hand to be sure it moves freely.
10. Check bolts, nuts, screws, terminals, and fittings for security.
11. Check to insure air supply 80 PSI (552 kPa) is connected to the dryer.
K SHUT DOWN INSTRUCTIONS
If the dryer is to be shut down (taken out of service) for a period of time, the following must be performed:
1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.
2. Discontinue the heat supply:
a. GAS MODELS ... discontinue the gas supply.
1) SHUT OFF external gas supply shutoff valve.
2) SHUT OFF internal gas supply shutoff valve located in the gas valve burner area.