* AWG Stranded Type Wire ... for individual lengths less than 100 feet.
(Motor lead type wire is recommended)
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is
affixed to the back of the dryer, at the upper right hand corner. In the case of
208 VAC or 230/240 VAC, the supply voltage must match the electric service
specifications of the data label exactly.
WARNING: 208 VAC and 230/240 Volts ARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time, without notice or
obligation.
ADE-120ES (80 Kw Electric Oven) Reversing, 3ø Motor
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC and 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES: A. Fuse ratings are dual element-time delay-current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to
appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3Ø dryers must be 3-pole type.
OVEN
SIZE
(KW)
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP
DRAW
MINIMUM
WIRE SIZE*
FUSING
CIRCUIT
BREAKER
50 Hz 60 Hz
Dual Element
Time Delay
80 208 3 --- 235 250 MCM 300 300
80 240 3 208 206 4/0 300 300
80 380 3 130 --- 1 175 175
80 380 4 130 --- 1 175 175
80 416 3 119 --- 1 150 150
80 416 4 119 --- 1 150 150
80 480 3 --- 107 2 150 150
80 480 4 --- 107 2 150 150
80 575 3/4 --- 86 3 125 125
80 600 3/4 --- 85 3 125 125