* AWG Stranded Type Wire ... for individual lengths less than 100 feet.
(Motor lead type wire is recommended)
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is
affixed to the back of the dryer, at the upper right hand corner. In the case of
208 VAC or 230/240 VAC, the supply voltage must match the electric service
specifications of the data label exactly.
WARNING: 208 VAC and 230/240 Volts ARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time, without notice or
obligation.
ADE-115 (60 Kw Electric Oven) Reversing, 3ø Motor
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC and 230/240 VAC ARE NOT THE SAME. When ordering ,specify exact voltage.
NOTES: A. Fuse ratings are dual element-time delay-current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size
according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3Ø dryers must be 3-pole type.
OVEN
SIZE
(Kw)
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MINIMUM
WIRE SIZE*
FUSING
CIRCUIT
BREAKER
50
Hz
60 Hz
Dual
Element
Time Delay
60 208 3ø 3 --- 180 3/0 250 250
60 240 3ø 3 159 157 2/0 200 200
60 380 3ø 3 99 --- 3 150 150
60 380 3ø 4 99 --- 3 150 150
60 416 3ø 3 91 --- 3 150 150
60 416 3ø 4 91 --- 3 150 150
60 480 3ø 3 --- 82 4 100 100
60 480 3ø 4 --- 82 4 100 100
60 575/600 3ø 3 / 4 --- 86 4 90 90